(+34) 976 731 533 info@acuvetbiotech.com

Turbovet Pig-MAP

Turbidimetric test for the determination of pig-MAP/ITIH4

Fast, automatic, precise, robust: all the advantages of a turbidimetric method with the reliability of a species-specific test. By testing pig-MAP, you can assess on-farm health and welfare, quantify stress, or evaluate inflammation in experimental trials.

Available formats

CATALOG NR
AC/PMT01
AC/PMT02
AC/PMST
AC/PMCT
DESCRIPTION
Turbovet pig-MAP 100 test. Complete Kit. Includes calibrators and controls.
Turbovet pig-MAP 200 test. Complete Kit. Includes calibrators and controls.
Turbovet pig-MAP calibrator.
Turbovet pig-MAP controls.

Uses and advantages of our test

Pig-MAP, also known as ITIH4, is one of the main porcine acute-phase proteins and represents an excellent biomarker of inflammation and distress in this species. Measuring pig-MAP enables detection of health problems and poor welfare on farms, and quantification of stress or inflammation in experimental studies; for example, drug or nutraceutical trials. Turbovet pig-MAP is the first commercially available test for measuring pig-MAP based on turbidimetry. Precise and reliable results are obtained in a few minutes, and analysis can be fully automated with any open chemistry analyzer, significantly reducing required time and costs. The reagents are very stable, and frequent calibration of the equipment is not necessary. Turbovet is an ideal analytical tool for quality control in production systems, animal-welfare certification, or for studies that require highly reliable and reproducible data.

TECHNICAL DATA

• Species-specific.
• Automatic: Can be run in any open clinical chemistry analyzer.
• Working range: 0-5 mg/mL.
• Assay time: 5 minutes.
• Reagents: ready to use and very stable.
• Free of interference by hemoglobin (20g/L), bilirubin (0.15 g/L) of triglycerides< <4 g/L.
Sample type: serum

ANALYTICAL PRINCIPLE:
Quantification by immunoturbidimetry. Pig-MAP from serum reacts with specific antibodies to form immunoaggregates. This causes an increase in turbidity in the reaction medium. The increase in turbidity is determined by photometric measurement and is proportional to pig-MAP concentration in the sample.

STANDARDIZATION:
The assay is calibrated with a porcine-specific standard, according to the European Reference Serum for Acute phase proteins (EU concerted Action QLK5-CT-1999-0153).

VALIDATION:
Validated by the Autonomous University of Barcelona according to CLSI and SEQC guidelines.

Related Posts

Acuvet Biotech at the 31 Word Buiatrics Congress

Acuvet Biotech at the 31 Word Buiatrics Congress

Acuvet Biotech will participate in the World Buitric Congress, where we will be presenting an oral communication and a poster. tAfter two years of waiting due to the pandemic, the 31 World Buiatrics Congress can finally be held in person, in Madrid, from 4-8 September...

New scientific publication

New scientific publication

A new automated turbidimetric immunoassay for the measurement of canine C-reactive protein. This paper published in Veterinary Clinical Pathology shows the validation of Turbovet canine CRP, our test for measuring C-reactive protein in dog serum. The objective of the...

Want to know more? Contact us

Acuvet Biotech

Contact us

(+34) 976 731 533

info@acuvetbiotech.com

Location

C/ Bari, 25 duplicado
50197 Zaragoza (SPAIN)

4 + 8 =

© Acuvet Biotech - 2021 | Developed by o10media | Privacy Policy